Page 1 - 5000V Master

i5000V MasterMS-9638 (V1.X) Server BoardG52-96381X19638v1.0-Preface.p65 2006/11/9, 下午 03:321

Page 2 - Technical Support

xSelecting the Management Type...C-3SCSI Bus Interface Definitions...

Page 3 - Safety Instructions

1-1Getting StartedGetting StartedChapter 1Thank you for choosing the 5000V Master (MS-9638v1.X), an excellent SSI CEB server board from MSI.Based on t

Page 4 - Micro-Star International

MS-9638 Server Board1-2Mainboard SpecificationsProcessor Support- Supports dual Intel® Xeon® (Dempsey/Woodcrest/Clovertown)processors in Socket LGA771

Page 5

1-3Getting StartedConnectorsBack Panel- 1 x PS/2 mouse port- 1 x PS/2 keyboard port- 1 x serial port- 1 x VGA port- 2 x USB 2.0 ports- 2 x individual

Page 6

MS-9638 Server Board1-45000V Master (MS-9638 v1.X) SSI CEB Server BoardMainboard LayoutBIOSSCSI1SYSFAN5SYSFAN2SYSFAN4SYSFAN6SYSFAN3IDE1JUSB2JUSB1CPUFA

Page 7

2-1Hardware SetupHardware SetupChapter 2This chapter provides you with the information abouthardware setup procedures. While doing the installation,be

Page 8 - CONTENTS

MS-9638 Server Board2-2Quick Components GuideJLANDIS1/2,p.2-17SYSFAN2/3/4/5/6, p.2-12FDD1, p.2-10COM2,p.2-14IDE1,p.2-10SATA0~5,p.2-11JUSB1/2,p.2-14SCS

Page 9

2-3Hardware SetupCPU (Central Processing Unit)This mainboard supports the latest Intel® Xeon® (Dempsey/Woodcrest/Clovertown) processors in Socket LGA7

Page 10

MS-9638 Server Board2-44. After confirming the CPU direction(indicated below with red circles)for correct mating, put down theCPU in the socket housin

Page 11 - Getting Started

2-5Hardware SetupInstalling the Intel CPU CoolerCPU cooler backplate6.Screw to secure the CPU cooler.7. Install another CPU fan sink ifnecessary.5.Con

Page 12 - Mainboard Specifications

iiCopyright NoticeThe material in this document is the intellectual property of MICRO-STARINTERNATIONAL. We take every care in the preparation of thi

Page 13 - Mounting

MS-9638 Server Board2-6Memory64x2=128 pin 56x2=112 pinDDRII240-pin, 1.8VMemory Population RulesFBD12FBD11FBD02FBD01Channel 1Channel 0Important1. To

Page 14 - Mainboard Layout

2-7Hardware SetupInstalling DDRII Modules1. The memory module has only one notch on the center and will only fit in the rightorientation.2. Insert the

Page 15 - Hardware Setup

MS-9638 Server Board2-8Power SupplyPIN SIGNAL13 +3.3V14 -12V15 GND16 PS-ON#17 GND18 GND19 GND20 Res21 +5V22 +5V23 +5V24 GNDPIN SIGNAL 1 +3.3V 2 +3.3V

Page 16 - Quick Components Guide

2-9Hardware SetupBack Panel Mouse/Keyboard ConnectorThe standard PS/2® mouse/keyboard DIN connector is for a PS/2® mouse/keyboard. USB PortsThe OHCI (

Page 17 - CPU (Central Processing Unit)

MS-9638 Server Board2-10ConnectorsFloppy Disk Drive Connector: FDD1The mainboard provides a standard floppy disk drive connector.FDD1ATA100 Hard Disk

Page 18 - Installing the LGA771 CPU

2-11Hardware SetupConnect to SATA connectorsTake out the dust coverand connect to the harddisk devicesSerial ATA cableSerial ATA Connectors: SATA0 ~ S

Page 19

MS-9638 Server Board2-12Fan Power Connectors: CPUFAN 1/2, SYSFAN 1/2/3/4/5/6The fan power connectors support system cooling fan with +12V. When connec

Page 20 - Important

2-13Hardware SetupLAN LED Connectors: JACT1, JACT2The LAN LED connectors are used to connect to LAN LEDs, which show the activityof the LAN. The JACT1

Page 21 - Installing DDRII Modules

MS-9638 Server Board2-14Front USB Connector: JUSB1, JUSB2The mainboard provides two USB 2.0 pinheaders (optional USB 2.0 bracket available)that are co

Page 22 - Power Supply

2-15Hardware SetupUltra320 SCSI Connector: SCSI1SCSI (Small Computer System Interface) is a parallel interface standard for attachingperipheral device

Page 23 - Back Panel

iiiSafety InstructionsCAUTION: Danger of explosion if battery is incorrectly replaced.Replace only with the same or equivalent type recommended by th

Page 24

MS-9638 Server Board2-16JumpersClear CMOS Jumper: JBAT1There is a CMOS RAM onboard that has a power supply from external battery to keepthe data of sy

Page 25

2-17Hardware SetupBIOS Recovery Jumper: J9Users can short connect pin#2-3 to recover the system BIOS. When the system isdone with the job, the buzzer

Page 26

MS-9638 Server Board2-18SlotsImportantWhen adding or removing expansion cards, make sure that you unplug thepower supply first. Meanwhile, read the do

Page 27 - Front Panel Connector: JFP1

3-1BIOS SetupChapter 3BIOS SetupThis chapter provides information on the BIOS Setupprogram and allows you to configure the system foroptimum use.You

Page 28 - Serial Port Connector: COM 2

3-2MS-9638 Server BoardEntering SetupImportant1.The items under each BIOS category described in this chapter are undercontinuous update for better sys

Page 29

3-3BIOS SetupGetting HelpAfter entering the Setup menu, the first menu you will see is the Main Menu.Main MenuThe main menu lists the setup functions

Page 30 - Clear CMOS Jumper: JBAT1

3-4MS-9638 Server Board MainUse this menu for basic system configurations, such as time, date etc. AdvancedUse this menu to set up the items of specia

Page 31 - BIOS Recovery Jumper: J9

3-5BIOS SetupMain System Time (hh:mm:ss)The time format is <Hour> <Minute> <Second>. System Date (mm:dd:yy)The date format is <Mo

Page 32

3-6MS-9638 Server Board[Tranfer Mode] Selects the method for transferring the databetween the hard disk and system memory[Ultra DMA Mode] Indicates th

Page 33 - BIOS Setup

3-7BIOS Setup System InformationPress <Enter> to view the hardware specifications of your system. System Memory, Extended MemoryThese items show

Page 34 - Entering Setup

ivFCC-B Radio Frequency Interference StatementThis equipment has beentested and found to complywith the limits for a Class Bdigital device, pursuant t

Page 35 - Control Keys

3-8MS-9638 Server BoardAdvanced Reset Configuration DataSelect [Yes] if you want to clear the Extended System configuration Data (ESCD)area. Large Dis

Page 36 - The Menu Bar

3-9BIOS Setup Advanced Chipset ControlPress <Enter> to enter the sub-menu and the following screen appears: USB Host ControllerThis setting disa

Page 37

3-10MS-9638 Server Board[Enhanced] SATA and PATA drives are auto-detected and placed(non-AHCI) in Native IDE mode. SATA RAID EnableThis feature allows

Page 38

3-11BIOS SetupAdvanced Processor OptionsPress <Enter> to enter the sub-menu and the following screen appears: Hyperthreading (auto detect functi

Page 39 - System Information

3-12MS-9638 Server Board Thermal Management 2 (auto detect function)This setting specifies the thermal technologies implemented in the Intel® processo

Page 40 - Advanced

3-13BIOS Setup Floppy Disk ControllerSelect [Enabled] if your system has a floppy disk controller (FDD) installed onthe system board and you wish to u

Page 41

3-14MS-9638 Server Board Console Redirection Com Port AddressThis setting enables/disables the Com port address for console connection. Baud RateThis

Page 42

3-15BIOS Setup DMI Event LoggingPress <Enter> to enter the sub-menu and the following screen appears: Event log validity/capacityThese items ind

Page 43

3-16MS-9638 Server BoardSecurity Supervisor Password Is, User Password IsThese items indicate the status of password settings. Set Supervisor Password

Page 44

3-17BIOS SetupPowerS3-related functions are available only when your BIOS supports S3 sleep mode.Important Power Button FunctionThis feature allows us

Page 45

vWEEE (Waste Electrical and Electronic Equipment) Statement9638v1.0-Preface.p65 2006/11/9, 下午 03:325

Page 46

3-18MS-9638 Server Board[Last State] Restores the system to the previous status before powerfailure or interrupt occurred. Resume On Modem RingThe ite

Page 47

3-19BIOS SetupPC Health Fan & Temperature MenuThese items display the current temperatures and fans’ speeds of the system. Auto FAN Speed ControlT

Page 48 - Security

3-20MS-9638 Server Board CPU1 Target Temp, CPU2 Target TempYou can select a fan value here. If the current temperature reaches to the minimumthreshol

Page 49

3-21BIOS SetupBootThese settings allow users to set the priority of the specified devices.You may usethe arrow keys ( ↑↓ ) to select the desired devic

Page 50

3-22MS-9638 Server BoardExit Exit Saving ChangesSave changes to CMOS and exit setup. Exit Discarding ChangesAbandon all changes and exit setup. Load S

Page 51 - PC Health

A-1Intel SATA RAIDIntel SATA RAID (Optional)Appendix AThe Southbridge provides a hybrid solution that com-bines six independent SATAII ports for suppo

Page 52

A-2MS-9638 Server BoardIntroductionImportant1. The least number of hard drives for RAID 0, RAID 1 or Matrix mode is 2.The least number of hard drives

Page 53

A-3Intel SATA RAIDBIOS ConfigurationAfter the above message shows, press <Ctrl> and <I> keys simultaneously to enterthe RAID Configuration

Page 54

A-4MS-9638 Server Board(1) Create RAID Volume1. Select option 1 “Create RAID Volume” and press <Enter> key. The followingscreen appears. Then in

Page 55 - Appendix A

A-5Intel SATA RAID3. In the Disk field, press <Enter> key and the following screen appears. Use<Space> key to select the disks you want to

Page 56 - Introduction

vi9638v1.0-Preface.p65 2006/11/9, 下午 03:326

Page 57 - BIOS Configuration

A-6MS-9638 Server Board 6.Then the following screen appears for you to confirm if you are sure tocreate the RAID volume. Press <Y> to continue.

Page 58 - 6.2.1002 ESB2

A-7Intel SATA RAID(2) Delete RAID VolumeHere you can delete the RAID volume, but please be noted that all data on RAIDdrives will be lost.Select optio

Page 59

A-8MS-9638 Server Board(3) Reset Disks to Non-RAIDSelect option 3 Reset Disks to Non-RAID and press <Enter> to delete the RAIDvolume and remove

Page 60

B-1Adaptec SATA RAIDAdaptec SATA RAID (Optional)Appendix BThe Southbridge provides a hybrid solution that com-bines six independent SATAII ports for s

Page 61

B-2MS-9638 Server BoardIntroductionImportant1. The least number of hard drives for RAID 0 or RAID 1 is 2. The leastnumber of hard drives for RAID 10 m

Page 62

B-3Adaptec SATA RAIDBIOS ConfigurationAfter the above message shows, press <Ctrl> and <A> keys simultaneously to enterthe RAID Configurati

Page 63 - Appendix B

B-4MS-9638 Server Board(1) Create RAID Volume1. Enter Array Configuration Utility. Select option “Create array” and press<Enter> key. The follow

Page 64

B-5Adaptec SATA RAIDThen in the Select drivers to create Array field, specify the devices andthen press the <Enter> key to go to the next field.

Page 65

B-6MS-9638 Server Board4. Then select the Create RAID via Quick Init, and select [Done] to finish thecreation.3. Then Enter the Array Label name, and

Page 66 - (1) Create RAID Volume

B-7Adaptec SATA RAID5. Enter Manager Arrays to confirm if the creation is finished.9638v1.0-Appendix B(Adaptec SATA RAID).p65 2006/11/9, 下午 03:337

Page 67 - Adaptec SATA RAID

vii9638v1.0-Preface.p65 2006/11/9, 下午 03:327

Page 68

B-8MS-9638 Server Board(2) Delete RAID VolumeHere you can delete the RAID volume, but please be noted that all data on RAIDdrives will be lost.Select

Page 69

B-9Adaptec SATA RAIDSelect [Delete], and press <Enter>. The following screen appears:Press <Y> key to accept the volume deletion.9638v1.0-

Page 70

C-1SCSI BIOSSCSI BIOS (Optional)Appendix CThis chapter provides information on the Small Com-puter System Interface (SCSI) BIOS setup utility andallow

Page 71

C-2MS-9638 Server BoardEntering SCSI BIOSControl KeysUse the following keys to navigate the SCSI BIOS menu items.Selecting the SCSI ChannelAfter enter

Page 72 - Appendix C

C-3SCSI BIOSSelecting the Management TypeThe following screen will appear after you select the SCSI channel you intend tomanage. The menu will list tw

Page 73 - Entering SCSI BIOS

C-4MS-9638 Server BoardConfigure/View SCSI SettingsSCSI Bus Interface DefinitionsSCSI Controller IDThe item is used to assign a SCSI ID to the SCSI co

Page 74 - Selecting the Management Type

C-5SCSI BIOSAdditional OptionsBoot Device ConfigurationPress <Enter> to enter the sub-menu screen.Boot SCSI ControllersSelect SCSI channel AIC-7

Page 75 - Configure/View SCSI Settings

C-6MS-9638 Server BoardSync Transfer Rate (MB/Sec)The field allows you to specify the maximum synchronous data transfer ratedepending on the type of e

Page 76 - Additional Options

C-7SCSI BIOSon-at-a-time during bootup, reducing the load on the computer’s power supply.Setting options: [Yes], [No].BIOS Multiple LUN SupportSelect

Page 77

C-8MS-9638 Server BoardPOST Display ModeThe field determines how much information about your SCSI controller anddevices appear on the screen during bo

Page 78

viiiCONTENTSCopyright Notice...iiTrademark

Page 79 - BIOS Information

C-9SCSI BIOSSelect the SCSI device which you want to manage by highlighting the item and press<Enter>. The following dialog box appears. Select

Page 80 - Disk Utilities

C-10MS-9638 Server BoardImportant1. It offers RAID level 0 (Striping), RAID level 1 (Mirroring and Duplexing),and RAID level 10 (A Stripe of Mirrors).

Page 81

ixBIOS Write Protect Jumper: JBIOS1...............2-17LAN Jumper: JLANDIS1, JLANDIS2.......