i5000V MasterMS-9638 (V1.X) Server BoardG52-96381X19638v1.0-Preface.p65 2006/11/9, 下午 03:321
xSelecting the Management Type...C-3SCSI Bus Interface Definitions...
1-1Getting StartedGetting StartedChapter 1Thank you for choosing the 5000V Master (MS-9638v1.X), an excellent SSI CEB server board from MSI.Based on t
MS-9638 Server Board1-2Mainboard SpecificationsProcessor Support- Supports dual Intel® Xeon® (Dempsey/Woodcrest/Clovertown)processors in Socket LGA771
1-3Getting StartedConnectorsBack Panel- 1 x PS/2 mouse port- 1 x PS/2 keyboard port- 1 x serial port- 1 x VGA port- 2 x USB 2.0 ports- 2 x individual
MS-9638 Server Board1-45000V Master (MS-9638 v1.X) SSI CEB Server BoardMainboard LayoutBIOSSCSI1SYSFAN5SYSFAN2SYSFAN4SYSFAN6SYSFAN3IDE1JUSB2JUSB1CPUFA
2-1Hardware SetupHardware SetupChapter 2This chapter provides you with the information abouthardware setup procedures. While doing the installation,be
MS-9638 Server Board2-2Quick Components GuideJLANDIS1/2,p.2-17SYSFAN2/3/4/5/6, p.2-12FDD1, p.2-10COM2,p.2-14IDE1,p.2-10SATA0~5,p.2-11JUSB1/2,p.2-14SCS
2-3Hardware SetupCPU (Central Processing Unit)This mainboard supports the latest Intel® Xeon® (Dempsey/Woodcrest/Clovertown) processors in Socket LGA7
MS-9638 Server Board2-44. After confirming the CPU direction(indicated below with red circles)for correct mating, put down theCPU in the socket housin
2-5Hardware SetupInstalling the Intel CPU CoolerCPU cooler backplate6.Screw to secure the CPU cooler.7. Install another CPU fan sink ifnecessary.5.Con
iiCopyright NoticeThe material in this document is the intellectual property of MICRO-STARINTERNATIONAL. We take every care in the preparation of thi
MS-9638 Server Board2-6Memory64x2=128 pin 56x2=112 pinDDRII240-pin, 1.8VMemory Population RulesFBD12FBD11FBD02FBD01Channel 1Channel 0Important1. To
2-7Hardware SetupInstalling DDRII Modules1. The memory module has only one notch on the center and will only fit in the rightorientation.2. Insert the
MS-9638 Server Board2-8Power SupplyPIN SIGNAL13 +3.3V14 -12V15 GND16 PS-ON#17 GND18 GND19 GND20 Res21 +5V22 +5V23 +5V24 GNDPIN SIGNAL 1 +3.3V 2 +3.3V
2-9Hardware SetupBack Panel Mouse/Keyboard ConnectorThe standard PS/2® mouse/keyboard DIN connector is for a PS/2® mouse/keyboard. USB PortsThe OHCI (
MS-9638 Server Board2-10ConnectorsFloppy Disk Drive Connector: FDD1The mainboard provides a standard floppy disk drive connector.FDD1ATA100 Hard Disk
2-11Hardware SetupConnect to SATA connectorsTake out the dust coverand connect to the harddisk devicesSerial ATA cableSerial ATA Connectors: SATA0 ~ S
MS-9638 Server Board2-12Fan Power Connectors: CPUFAN 1/2, SYSFAN 1/2/3/4/5/6The fan power connectors support system cooling fan with +12V. When connec
2-13Hardware SetupLAN LED Connectors: JACT1, JACT2The LAN LED connectors are used to connect to LAN LEDs, which show the activityof the LAN. The JACT1
MS-9638 Server Board2-14Front USB Connector: JUSB1, JUSB2The mainboard provides two USB 2.0 pinheaders (optional USB 2.0 bracket available)that are co
2-15Hardware SetupUltra320 SCSI Connector: SCSI1SCSI (Small Computer System Interface) is a parallel interface standard for attachingperipheral device
iiiSafety InstructionsCAUTION: Danger of explosion if battery is incorrectly replaced.Replace only with the same or equivalent type recommended by th
MS-9638 Server Board2-16JumpersClear CMOS Jumper: JBAT1There is a CMOS RAM onboard that has a power supply from external battery to keepthe data of sy
2-17Hardware SetupBIOS Recovery Jumper: J9Users can short connect pin#2-3 to recover the system BIOS. When the system isdone with the job, the buzzer
MS-9638 Server Board2-18SlotsImportantWhen adding or removing expansion cards, make sure that you unplug thepower supply first. Meanwhile, read the do
3-1BIOS SetupChapter 3BIOS SetupThis chapter provides information on the BIOS Setupprogram and allows you to configure the system foroptimum use.You
3-2MS-9638 Server BoardEntering SetupImportant1.The items under each BIOS category described in this chapter are undercontinuous update for better sys
3-3BIOS SetupGetting HelpAfter entering the Setup menu, the first menu you will see is the Main Menu.Main MenuThe main menu lists the setup functions
3-4MS-9638 Server Board MainUse this menu for basic system configurations, such as time, date etc. AdvancedUse this menu to set up the items of specia
3-5BIOS SetupMain System Time (hh:mm:ss)The time format is <Hour> <Minute> <Second>. System Date (mm:dd:yy)The date format is <Mo
3-6MS-9638 Server Board[Tranfer Mode] Selects the method for transferring the databetween the hard disk and system memory[Ultra DMA Mode] Indicates th
3-7BIOS Setup System InformationPress <Enter> to view the hardware specifications of your system. System Memory, Extended MemoryThese items show
ivFCC-B Radio Frequency Interference StatementThis equipment has beentested and found to complywith the limits for a Class Bdigital device, pursuant t
3-8MS-9638 Server BoardAdvanced Reset Configuration DataSelect [Yes] if you want to clear the Extended System configuration Data (ESCD)area. Large Dis
3-9BIOS Setup Advanced Chipset ControlPress <Enter> to enter the sub-menu and the following screen appears: USB Host ControllerThis setting disa
3-10MS-9638 Server Board[Enhanced] SATA and PATA drives are auto-detected and placed(non-AHCI) in Native IDE mode. SATA RAID EnableThis feature allows
3-11BIOS SetupAdvanced Processor OptionsPress <Enter> to enter the sub-menu and the following screen appears: Hyperthreading (auto detect functi
3-12MS-9638 Server Board Thermal Management 2 (auto detect function)This setting specifies the thermal technologies implemented in the Intel® processo
3-13BIOS Setup Floppy Disk ControllerSelect [Enabled] if your system has a floppy disk controller (FDD) installed onthe system board and you wish to u
3-14MS-9638 Server Board Console Redirection Com Port AddressThis setting enables/disables the Com port address for console connection. Baud RateThis
3-15BIOS Setup DMI Event LoggingPress <Enter> to enter the sub-menu and the following screen appears: Event log validity/capacityThese items ind
3-16MS-9638 Server BoardSecurity Supervisor Password Is, User Password IsThese items indicate the status of password settings. Set Supervisor Password
3-17BIOS SetupPowerS3-related functions are available only when your BIOS supports S3 sleep mode.Important Power Button FunctionThis feature allows us
vWEEE (Waste Electrical and Electronic Equipment) Statement9638v1.0-Preface.p65 2006/11/9, 下午 03:325
3-18MS-9638 Server Board[Last State] Restores the system to the previous status before powerfailure or interrupt occurred. Resume On Modem RingThe ite
3-19BIOS SetupPC Health Fan & Temperature MenuThese items display the current temperatures and fans’ speeds of the system. Auto FAN Speed ControlT
3-20MS-9638 Server Board CPU1 Target Temp, CPU2 Target TempYou can select a fan value here. If the current temperature reaches to the minimumthreshol
3-21BIOS SetupBootThese settings allow users to set the priority of the specified devices.You may usethe arrow keys ( ↑↓ ) to select the desired devic
3-22MS-9638 Server BoardExit Exit Saving ChangesSave changes to CMOS and exit setup. Exit Discarding ChangesAbandon all changes and exit setup. Load S
A-1Intel SATA RAIDIntel SATA RAID (Optional)Appendix AThe Southbridge provides a hybrid solution that com-bines six independent SATAII ports for suppo
A-2MS-9638 Server BoardIntroductionImportant1. The least number of hard drives for RAID 0, RAID 1 or Matrix mode is 2.The least number of hard drives
A-3Intel SATA RAIDBIOS ConfigurationAfter the above message shows, press <Ctrl> and <I> keys simultaneously to enterthe RAID Configuration
A-4MS-9638 Server Board(1) Create RAID Volume1. Select option 1 “Create RAID Volume” and press <Enter> key. The followingscreen appears. Then in
A-5Intel SATA RAID3. In the Disk field, press <Enter> key and the following screen appears. Use<Space> key to select the disks you want to
vi9638v1.0-Preface.p65 2006/11/9, 下午 03:326
A-6MS-9638 Server Board 6.Then the following screen appears for you to confirm if you are sure tocreate the RAID volume. Press <Y> to continue.
A-7Intel SATA RAID(2) Delete RAID VolumeHere you can delete the RAID volume, but please be noted that all data on RAIDdrives will be lost.Select optio
A-8MS-9638 Server Board(3) Reset Disks to Non-RAIDSelect option 3 Reset Disks to Non-RAID and press <Enter> to delete the RAIDvolume and remove
B-1Adaptec SATA RAIDAdaptec SATA RAID (Optional)Appendix BThe Southbridge provides a hybrid solution that com-bines six independent SATAII ports for s
B-2MS-9638 Server BoardIntroductionImportant1. The least number of hard drives for RAID 0 or RAID 1 is 2. The leastnumber of hard drives for RAID 10 m
B-3Adaptec SATA RAIDBIOS ConfigurationAfter the above message shows, press <Ctrl> and <A> keys simultaneously to enterthe RAID Configurati
B-4MS-9638 Server Board(1) Create RAID Volume1. Enter Array Configuration Utility. Select option “Create array” and press<Enter> key. The follow
B-5Adaptec SATA RAIDThen in the Select drivers to create Array field, specify the devices andthen press the <Enter> key to go to the next field.
B-6MS-9638 Server Board4. Then select the Create RAID via Quick Init, and select [Done] to finish thecreation.3. Then Enter the Array Label name, and
B-7Adaptec SATA RAID5. Enter Manager Arrays to confirm if the creation is finished.9638v1.0-Appendix B(Adaptec SATA RAID).p65 2006/11/9, 下午 03:337
vii9638v1.0-Preface.p65 2006/11/9, 下午 03:327
B-8MS-9638 Server Board(2) Delete RAID VolumeHere you can delete the RAID volume, but please be noted that all data on RAIDdrives will be lost.Select
B-9Adaptec SATA RAIDSelect [Delete], and press <Enter>. The following screen appears:Press <Y> key to accept the volume deletion.9638v1.0-
C-1SCSI BIOSSCSI BIOS (Optional)Appendix CThis chapter provides information on the Small Com-puter System Interface (SCSI) BIOS setup utility andallow
C-2MS-9638 Server BoardEntering SCSI BIOSControl KeysUse the following keys to navigate the SCSI BIOS menu items.Selecting the SCSI ChannelAfter enter
C-3SCSI BIOSSelecting the Management TypeThe following screen will appear after you select the SCSI channel you intend tomanage. The menu will list tw
C-4MS-9638 Server BoardConfigure/View SCSI SettingsSCSI Bus Interface DefinitionsSCSI Controller IDThe item is used to assign a SCSI ID to the SCSI co
C-5SCSI BIOSAdditional OptionsBoot Device ConfigurationPress <Enter> to enter the sub-menu screen.Boot SCSI ControllersSelect SCSI channel AIC-7
C-6MS-9638 Server BoardSync Transfer Rate (MB/Sec)The field allows you to specify the maximum synchronous data transfer ratedepending on the type of e
C-7SCSI BIOSon-at-a-time during bootup, reducing the load on the computer’s power supply.Setting options: [Yes], [No].BIOS Multiple LUN SupportSelect
C-8MS-9638 Server BoardPOST Display ModeThe field determines how much information about your SCSI controller anddevices appear on the screen during bo
viiiCONTENTSCopyright Notice...iiTrademark
C-9SCSI BIOSSelect the SCSI device which you want to manage by highlighting the item and press<Enter>. The following dialog box appears. Select
C-10MS-9638 Server BoardImportant1. It offers RAID level 0 (Striping), RAID level 1 (Mirroring and Duplexing),and RAID level 10 (A Stripe of Mirrors).
ixBIOS Write Protect Jumper: JBIOS1...............2-17LAN Jumper: JLANDIS1, JLANDIS2.......
Comments to this Manuals