B-12
Intel RAID
Degraded RAID Array
A RAID 1, RAID 5 or RAID 10 volume s reported as degraded when one of ts hard drve
members fals or s temporarly dsconnected, and data mrrorng s lost. As a result, the
system can only utlze the remanng functonal hard drve member. To re-establsh
data mrrorng and restore data redundancy, refer to the procedure below that corre-
sponds to the current stuaton.
Mssng Hard Drve Member
Make sure the system s powered o.
Reconnect the hard drve.
Reboot the system to Wndows; the rebuld wll occur automatcally.
Faled Hard Drve Member
Make sure the system s powered o.
Replace the faled hard drve wth a new one that s of equal or greater capacty.
Reboot the system to Intel RAID Opton ROM by press <Ctrl> and <I> keys smul
-
taneously durng the Power-On Self Test (POST).
1.
2.
3.
1.
2.
3.
Select the port of the destnaton dsk for rebuldng, and then press ENTER.
4.
RAID Volumes
ID Name Level Strp Sze Status Bootable
0 Volume0 RAID 1(Mrror) N/A XXX.XGB
Degraded Yes
Physcal Dsks:
Port Devce Model Seral # Sze Type/Status(Vol ID)
1 XXXXXXXXXXXXX XXXXXXXXXXXXX XXX.XGB Member Dsk (0)
2 XXXXXXXXXXXXX XXXXXXXXXXXXX XXX.XGB Member Dsk (0)
Press <CTRL-I> to enter Conguraton Utlty..
DISK / VOLUME INFORMATION
[ ]
4. Recovery Volume Optons
4. Recovery Volume Optons
5. Ext
RAID Volumes :
None dened.
Physcal Devces :
Port Devce Model Seral # Sze Type/Status (Vol ID)
1 XXXX-XXXXXXXX XXXXXXXXXXXXXX XXX.XGB Non-RAID Dsk
2 XXXX-XXXXXXXX XXXXXXXXXXXXXX XXX.XGB Non-RAID Dsk
[ ↑↓] - Select [ESC] - Ext [ENTER] - Select Menu
1. Create RAID Volume
2. Delete RAID Volume
“Degraded” volume and dsk avalable for rebuldng detected. Selectng
a dsk ntates a rebuld. Rebuld completes n the operatng system.
[ ]
DEGRADED VOLUME DETECTED
Select the port of the destnaton dsk for rebuldng (ESC to ext):
[ ↑↓] - Prevous/ Next [ENTER] - Select [ESC] - Ext
Port Drve Model Seral # Sze
1 XXXX-XXXXXXXX XXXXXXXXXXXXXX XXX.XGB
[ ]
MAIN MENU