MSI MS-9246 1U Instruction Manual

Browse online or download Instruction Manual for Motherboards MSI MS-9246 1U. MSI MS-9246 1U Instruction manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 123
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews

Summary of Contents

Page 1 - MS-9246 1U Rackmount Server

iEnglish VersionG52-S9246X1MS-9246 1U Rackmount Server

Page 2 - Micro-Star International

1-3Getting StartedEar SetRail SetPower Supply OptionsSingle Power 1 + 1 Redundant Power1 Redundant Power

Page 3 - Technical Support

B-5Adaptec SATA RAID Utility for Intel ICH5R2. Installing the Driver in an Existing Windows SystemIn this scenario, you are installing a driver in a s

Page 4 - Safety Instructions

B-6MS-9246 1U Rackmount Server4. Installing SuSE Linux 8.0 or 8.1 Installing the Driver in a New Linux SystemIn this scenario, you are installing

Page 5 - CONTENTS

B-7Adaptec SATA RAID Utility for Intel ICH5RInstalling Adaptec Storage Manager – Browser Edition1. OverviewThis chapter discusses the installation pro

Page 6

B-8MS-9246 1U Rackmount Server4. Installing Adaptec Storage Manager on WindowsTo install Adaptec Storage Manager – Browser Edition:1. Verify that a su

Page 7

B-9Adaptec SATA RAID Utility for Intel ICH5R Configuring Internet Browsers on WindowsIf you are managing a local storage array and your computer

Page 8 - Chapter 1. Getting

B-10MS-9246 1U Rackmount ServerConfiguring Netscape Navigator for Local ManagementTo configure Netscape Navigator:1. Log in to your computer with admi

Page 9 - Packing Checklist

B-11Adaptec SATA RAID Utility for Intel ICH5R5. Installing Adaptec Storage Manager on LinuxTo install Adaptec Storage Manager on a Linux computer and

Page 10 - Getting Started

B-12MS-9246 1U Rackmount ServerUsing Adaptec Storage Manager – Browser Edition1. OverviewThis section describes how to use Adaptec Storage Manager – B

Page 11 - System Overview

B-13Adaptec SATA RAID Utility for Intel ICH5R2. Architecture OverviewA locally managed system requires all of these components: A supported Web brows

Page 12 - Front Bezel

B-14MS-9246 1U Rackmount ServerNotes: When running Adaptec Storage Manager for the first time:You need to install a security certificate if you chose

Page 13

1-4MS-9246 1U Rackmount ServerSystem OverviewThis section shows the configuration of the MS-9246 from different angles,and the connectors and buttons

Page 14 -  Front Bezel LEDs

B-15Adaptec SATA RAID Utility for Intel ICH5R6. The BasicsAn example of a typical Adaptec Storage Manager – Browser Edition screen isshown below.

Page 15

B-16MS-9246 1U Rackmount Serverto amber, indicating that clicking any of them will display an additional windowwith information and options specific t

Page 16

B-17Adaptec SATA RAID Utility for Intel ICH5RView is the default display mode and when expanded, will show the followinginformation about each device:

Page 17 -  Rear Bezel LEDs

B-18MS-9246 1U Rackmount ServerFor detailed instructions on using these buttons, refer to the online Help.The main area of the Logical Devices view is

Page 18

B-19Adaptec SATA RAID Utility for Intel ICH5RThe Adaptec RAID Configuration (ARC) utility is an embedded BIOS utility that includes:     Array Co

Page 19 - System Specifications

B-20MS-9246 1U Rackmount Server3. From the ACU menu, select Manage Arrays.4. Select the array you wish to delete and press Delete.5. In the Array Prop

Page 20

B-21Adaptec SATA RAID Utility for Intel ICH5R4. Create RAID via allows you to select between the different creation methodsfor RAID 0 and RAID 1. The

Page 21

B-22MS-9246 1U Rackmount Server Initializing Disk DrivesIf an installed disk does not appear in the disk selection list for creating a new arrayo

Page 22

B-23Adaptec SATA RAID Utility for Intel ICH5RGlossaryAactivitySee task.ACUArray Configuration Utility. An application used to create, configure, and m

Page 23 - MS-9146 v1.X Server Board

B-24MS-9246 1U Rackmount ServerCcacheFast-access memory on the controller that serves as intermediate storage for datathat is read from, or written to

Page 24 - PC Alert™ III

1-5Getting StartedCD-ROM Drive1 Slim CD-ROM DriveFloppy Disk Drive2 Slim Floppy Disk DriveHDD Bay3 Swappable Hard Disk Drive BaysPort4 Serial Port

Page 25 - Hardware

B-25Adaptec SATA RAID Utility for Intel ICH5Rdrive LEDDisk indicator LED that illuminates during read or write operations.EeventNotification or alert

Page 26 - System Assembly Flowchart

B-26MS-9246 1U Rackmount Serverinitialized arrayAn array that is ready for data reads and writes. Arrays can be initialized by build orclear.Llegacy d

Page 27 - System Hardware

B-27Adaptec SATA RAID Utility for Intel ICH5RQquick initAn array initialized using the Quick Init option is available immediately, with no on-going ba

Page 28 - System Assembly

B-28MS-9246 1U Rackmount Serversingle-level arrayArray created from one or more segments. See also volume, spanned volume, RAID0, RAID 1.snapshotInsta

Page 29 - Replacing the Chassis Cover

1-6MS-9246 1U Rackmount ServerLED6 Power LEDThis indicator shows the power status of the system. It glows when the mainpower is turned on.7 HDD Acti

Page 30 - CPU, Heatsink, and Fan Duct

1-7Getting Started Front Bezel LEDsLED Color State DescriptionPower/Sleep Green On Legacy power on/ACPI S0 stateBlink (~1/sec) Sleep/ACPI S1 st

Page 31

1-8MS-9246 1U Rackmount Server Diagnostic LEDs: DLED1/DLED2/DLED3/DLED4Memory LEDs:D29/D30/D31/D32/D33/D35Component LEDs and four Diagnostic LED

Page 32 - Memory Bus Features

1-9Getting StartedD-LEDs DescriptionProcessor Initialization- This will show information regarding the processor (like brandname, system bus, etc...)T

Page 33 - Memory Population Rules

1-10MS-9246 1U Rackmount ServerRear ViewRear Bezel1 VGA Port2 Gigabit LAN Jacks3 USB Ports4 Serial Port5 NMI Switch6 System ID Button7 S

Page 34 - PCI Expansion Card

1-11Getting StartedMouse/Keyboard ConnectorSerial PortPIN SIGNAL1DCD2 SIN3 SOUT4 DTR5 GND6 DSR7 RTS8 CTS9RI1 2 3 4 56 7 8 9Pin De

Page 35

1-12MS-9246 1U Rackmount ServerSystem SpecificationsMainboard MS-9146 server boardCPU Dual Intel® XeonTM (800MHz FSB) processors in 604-pin package

Page 36 - PCI Riser Card (Optional)

iiManual Rev: 1.0Release Date: July 2004FCC-A Radio Frequency Interference StatementThis equipment has been tested and found to comply with the limits

Page 37 - SCSI HDD

1-13Getting Started 1 serial port 1 VGA port 2 RJ-45 Gigabit LAN jacks NMI switch/system ID button/system ID LEDNetwork Intel® 82546GB Gigabit Et

Page 38

1-14MS-9246 1U Rackmount ServerMode Refresh Minimum Amount of Memory Requiredrate(Hz)640x480 60640X480 72640X480 75640X480 90640X480 100800X600 60800X

Page 39 - Serial ATA HDD

1-15Getting StartedMSI Server Management IPMI 1.5 (optional) MSI-9569 BMC card (with QLogic Zircon UL BMC) and MSI iConsole AP supportIPMI 1.5 (optio

Page 40

1-16MS-9246 1U Rackmount ServerMainboard LayoutMS-9146 v1.X Server BoardBATT+ATIRADEONIntelFW82546GBGigabit LANCOM1IntelFW82801ERAdaptecAIC-7902WJPWR1

Page 41 - Rack Mounting

1-17Getting StartedMSI Special FeaturesPC Alert™ IIIThe PC AlertTM III is a utility you can find inthe CD-ROM disk. The utility is just like your PCd

Page 42 - Chassis Rails

2-1System HardwareChapter 2. SystemHardwareSystem HardwareThis chapter provides instructions on the hardware installationof the MS-9246 in two section

Page 43

2-2MS-9246 1U Rackmount ServerSystem Assembly FlowchartThe following flowchart shows basic system assembly procedures. Pleasenote that always wear ant

Page 44 - Rack Rails

2-3System HardwareINSTALLRISER CARDSINSTALLHARD DISK DRIVESCONNECT HDD, FDD,CD-ROM CABLES& POWER CORDSREPLACERISER CARD BRACKETFINISHCHECK IF ALL

Page 45 - Cable Arm (Optional)

2-4MS-9246 1U Rackmount ServerSystem AssemblyRemoving the Chassis Cover1. Loosen the thumbscrew on the rear bezel of the system.2. Press the release b

Page 46

2-5System HardwareReplacing the Chassis Cover1. Replace the front chassis cover and slide it backwards. Replace the rear chassiscover and slide it for

Page 47 - Chassis into the Rack

iiiCopyright NoticeThe material in this document is the intellectual property of MICRO-STARINTERNATIONAL. We take every care in the preparation of th

Page 48 - Chassis off the Rack

2-6MS-9246 1U Rackmount Server4. Place the CPU on top of the socket. Make sure to align thegold arrow on the CPU with the arrow key on the socket.The

Page 49 - Chapter 3. Mainboard

2-7System Hardware5. Place the heat sink on top of CPU1 and secure the screws on both sides.7. Install the second heatsink.Note: The heat sink has to

Page 50

2-8MS-9246 1U Rackmount ServerDDR MemoryMemory Bus Features Support for direct connect of two DDR channel interfaces, DDR266/DDR333 tech-nology Full

Page 51 - Mainboard Hardware

2-9System HardwareMemory Population RulesThe mainboard supports both single- & dual-channel modes. Install at least oneDIMM module on the slots. Y

Page 52

2-10MS-9246 1U Rackmount ServerPCI Expansion Card1. Locate the riser card bracket on the chassis. A standoff guide is designed asalignment guidance fo

Page 53

2-11System Hardware4. Install the second PCI expansion cardif necessary.5. Place the riser card bracket on top of the PCI slots on the motherboard. Al

Page 54

2-12MS-9246 1U Rackmount ServerPCI Riser Card (Optional)Apart from the standard PCI riser cards assembled in the system, an optional risercard is avai

Page 55 - Installing DDR Modules

2-13System Hardware1. To release the hot-swapping HDD tray, flip open the tray lever and pull the tray outof the bay.2. Unscrew the HDD tray and take

Page 56 - Power Supply

2-14MS-9246 1U Rackmount Server4. Insert the HDD set into the bay and press the lever back in place.3. At the sides of the HDD are four screw holes, t

Page 57 - Connectors

2-15System HardwareSerial ATA HDD1. To release the hot-swapping HDD holder, unscrew it and pull it out.3. Unscrew the HDD tray and take the tray out.2

Page 58 - Optional Serial ATA cable

iv1. Always read the safety instructions carefully.2. Keep this User’s Manual for future reference.3. Keep this equipment away from humidity.4. Lay th

Page 59

2-16MS-9246 1U Rackmount Server5. Insert the HDD set into the bay andpush it back in place.6. Screw the HDD set securely back tothe system.4. At the s

Page 60 - 5-pin IPMB Connector: CN3

2-17System HardwareRack MountingChassis Ears1. Insert the chassis ear into the chassis (as marked below).2. Push it in until it fits firmly. Screw to

Page 61 - Clear CMOS Jumper: JBAT1

2-18MS-9246 1U Rackmount Server2. Pull the chassis rail gently out until the locking tab locks the rail.3. Simultaneously press down the locking tab a

Page 62 - Clear Event Log Jumper: J8

2-19System Hardware5. On each side of the chassis are three hooks to lock the chassis rail. First align thechassis hooks with the holes on the rail. S

Page 63 - SO DIMM (Small Outline DIMM)

2-20MS-9246 1U Rackmount ServerRack Rails1. Locate the triangle mark on the rackand install 3 screw holders to the rackas shown.2. Align the rack rail

Page 64 - Chapter 4. BIOS Setup

2-21System HardwareCable Arm (Optional)An optional cable arm is available to helptidy the system cables up.The cable arm attaches to the rear of these

Page 65 - Entering Setup

2-22MS-9246 1U Rackmount Server6. Users may disassemble the cable arm following the above procedures in reverseorder.4. Simultaneously press down the

Page 66 - General Help <F1>

2-23System HardwareNote: The chassis rail is designed with a locking tab which can (1) hold thesystem firmly to the rack, and (2) lock the system half

Page 67 - The Menu Bar

2-24MS-9246 1U Rackmount ServerChassis off the Rack2. The system will be locked halfwaywhile being pulled out. Simultaneouslypress down the locking ta

Page 68 - BIOS Setup

3-1Mainboard HardwareChapter 3. MainboardHardwareMainboard HardwareThis chapter provides you with the information about hard-ware setup procedures. Wh

Page 69

vCONTENTSFCC-A Radio Frequency Interference Statement ... iiCopyright Notice ...

Page 70

3-2MS-9246 1U Rackmount ServerQuick Components GuideBATT+BIOSmPGA604mPGA604DDR DIMM1~6, p.3-5JPWR1, p.3-8USB1, p.3-9COM2, p.3-12SATA1/2, p.3-10CPU1/2,

Page 71 - System Summary

3-3Mainboard HardwareThe mainboard supports Single/Dual Intel® Xeon™ processor(s). Themainboard uses two CPU sockets called Socket 603/604 for easy CP

Page 72 - Advanced

3-4MS-9246 1U Rackmount Server1. Please turn off the power andunplug the power cord beforeinstalling the CPU.2. Pull the lever sideways awayfrom the s

Page 73

3-5Mainboard HardwareMemoryThe mainboard provides 6 slots for 184-pin DDR DIMM (Double In-Line MemoryModule) modules. You can install PC2100/DDR266 or

Page 74

3-6MS-9246 1U Rackmount ServerMemory Population RulesThe mainboard supports both single- & dual-channel modes. Install at least oneDIMM module on

Page 75

3-7Mainboard HardwareInstalling DDR Modules1. The DDR DIMM has only one notch on the center of module. The module will onlyfit in the right orientatio

Page 76

3-8MS-9246 1U Rackmount ServerPower SupplyBefore inserting the power supply connector, always make sure that all com-ponents are installed properly to

Page 77

3-9Mainboard HardwareThe mainboard provides connectors to connect to FDD, IDE HDD, case, LAN,USB ports, CPU/system power supply fans, ... and etc.Conn

Page 78

3-10MS-9246 1U Rackmount ServerSerial ATA RAID 0, 1 Connectors: SATA1, SATA2 (Optional)The southbridge Intel® ICH5R provides a hybrid solution that co

Page 79 - IPMI (Optional)

3-11Mainboard HardwareUltra320 SCSI Connectors: SCSI1/SCSI2 (Optional)SCSI (Small Computer System Interface) is a parallel interface standard forattac

Page 80

viChapter 3. Mainboard Hardware ... 3-1Quick Components Guide ...

Page 81

3-12MS-9246 1U Rackmount ServerSerial Port Connector: COM 2The mainboard provides one 9-pin header as serial port COM 2. The port is a16550A high spee

Page 82 - Security

3-13Mainboard HardwareThe motherboard provides the following jumpers for you to set the computer’sfunction. This section will explain how to change yo

Page 83

3-14MS-9246 1U Rackmount ServerBIOS Recovery Jumper: CN6Users can short connect pin#2-3 to recover the system BIOS with a RecoveryFloppy. When the sys

Page 84

3-15Mainboard HardwareSlotsPCI (Peripheral Component Interconnect) SlotsThe motherboard provides two 64-bit PCI-X slots, one PCI Express x4 slot, ando

Page 85

4-1BIOS SetupChapter 4. BIOS SetupThis chapter provides information on the BIOS Setup programand allows you to configure the system for optimum use.

Page 86 - (Optional)

4-2MS-9246 1U Rackmount ServerEntering SetupControl KeysPower on the computer and the system will start POST (Power On Self Test)process. When the mes

Page 87 - Entering SCSI BIOS

4-3BIOS SetupGetting HelpAfter entering the Setup menu, the first menu you will see is the Main Menu.Main MenuThe main menu lists the setup functions

Page 88 - SCSI BIOS Setup

4-4MS-9246 1U Rackmount ServerOnce you enter PhoenixBIOS Setup Utility, the Main Menu will appear on thescreen. On the Main Menu screen, you will see

Page 89

4-5BIOS SetupSecurityUse this menu to set Supervisor and User Passwords.BootUse this menu to specify the priority of boot devices.ExitThis menu allows

Page 90 - Additional Options

4-6MS-9246 1U Rackmount ServerThe items inside the Main menu are for basic system information andconfiguration. Each item includes none, one or more s

Page 91

viiAppendix A: SCSI BIOS Setup (Optional) ... A-1Entering SCSI BIOS ...

Page 92

4-7BIOS SetupIf you select [Manual], related information is asked to be entered to the followingitems. Enter the information directly from the keyboar

Page 93 - BIOS Information

4-8MS-9246 1U Rackmount ServerBIOS VersionThis setting shows the BIOS version.Processor SpeedIt shows the processor speed.Processor 1/2 CPU IDIt shows

Page 94 - Disk Utilities

4-9BIOS SetupProcessor SettingsPress <Enter> to view the settings of the onboard CPU(s).Hyper-Threading TechnologyThe processor uses Hyper-Threa

Page 95 - Verify Disk Media

4-10MS-9246 1U Rackmount ServerAdvanced Chipset ControlThe sub-menu is used to configure chipset features for optimal system performance.Enable Multim

Page 96 - Intel ICH5R (Optional)

4-11BIOS SetupSerial ATAThis setting allows you to enable or disable the onchip Serial-ATA controller.Settings: [Enabled], [Disabled].Native Mode Oper

Page 97

4-12MS-9246 1U Rackmount ServerEmbedded SCSI (Optional)The sub-menu is used to configure the onboard SCSI device.SCSI Controller (Optional)Use this fe

Page 98

4-13BIOS SetupInterruptIt specifies the interrupt for Port A/Port B. Options: [IRQ 3], [IRQ 4].PS/2 MouseIf your system has a PS/2 mouse port and you

Page 99 - Installing the Driver

4-14MS-9246 1U Rackmount ServerDMI Event LoggingPress PgUp/<+> or PgDn/<-> to view DMI event logging.View DMI Event LogPress [Enter] to vi

Page 100

4-15BIOS SetupBIOS Redirection PortThis feature selects the serial port to use for Console Redirection. [Disabled]completely disables Console Redirect

Page 101

4-16MS-9246 1U Rackmount ServerThis setup screen appears only when the MS-9569 BMC card (for ServerManagement) is installed on the mainboard. Press Pg

Page 102 -  On Linux

1-1Getting StartedChapter 1. GettingStartedGetting StartedThe MS-9246 1U Rackmount Server is a high-performancebarebone system powered by dual Intel®

Page 103

4-17BIOS SetupChange COM Port SettingThis setting controls the COM port setting.COM Port on BMCThis setting disables/enables the COM port on BMC.Syste

Page 104

4-18MS-9246 1U Rackmount ServerSystem Event LogSEL Entry Number = 1SEL Record ID = 0010SEL Record Type = 02 - System Event RecordTi

Page 105

4-19BIOS SetupSecurityThis section lets you set security passwords to control access to the systemat boot time and/or when entering the BIOS setup pro

Page 106

4-20MS-9246 1U Rackmount ServerPassword on bootChoosing [Enabled] requires a password on boot. It requires prior setting of thesupervisor password. If

Page 107 - 1. Overview

4-21BIOS SetupBootCD-ROM Drive, Removable Devices, Hard DriveThese are the generic types of devices on your system from which you can boot anoperating

Page 108 - 3. Logging In

4-22MS-9246 1U Rackmount ServerExit Saving ChangesWhen you want to quit the Setup menu, you can select this option to save thechanges and quit.Exit Di

Page 109 - 5. Registering Your Software

A-1SCSI BIOS SetupThis chapter provides information on the Small Computer Sys-tem Interface (SCSI) BIOS setup utility and allows you to configurethe S

Page 110 - 6. The Basics

A-2MS-9246 1U Rackmount ServerEntering SCSI BIOSControl KeysUse the following keys to navigate the SCSI BIOS menu items.Selecting the SCSI ChannelAfte

Page 111

A-3SCSI BIOS SetupConfigure/View SCSI Controller SettingsUse this option for SCSI controller configurations.SCSI Disk UtilitiesUse this option to mana

Page 112 -  Logical Devices

A-4MS-9246 1U Rackmount ServerConfigure/View SCSI Controller SettingsSCSI Bus Interface DefinitionsSCSI Controller IDThe item is used to assign a SCSI

Page 113

1-2MS-9246 1U Rackmount ServerUnpack the package and check if all items listed below are present. If any itemcontained in the package is damaged or mi

Page 114 -  Managing Arrays

A-5SCSI BIOS Setupthe SCSI bus is necessary. Proper termination can ensure signal on the SCSI bus willnot reflect and cause data loss or errors. Setti

Page 115 -  Creating Arrays

A-6MS-9246 1U Rackmount ServerSync Transfer Rate (MB/Sec)The field allows you to specify the maximum synchronous data transfer ratedepending on the ty

Page 116

A-7SCSI BIOS SetupSend Start Unit CommandWhen set to Yes, the SCSI controller sends the Start Unit command to thespecified SCSI device during bootup.

Page 117 -  Initializing Disk Drives

A-8MS-9246 1U Rackmount ServerPOST Display ModeThe field determines how much information about your SCSI controller anddevices appear on the screen du

Page 118 - Glossary

A-9SCSI BIOS SetupDisk UtilitiesAIC-7902 A at slot 0A, 03:07:00SCSI ID#0: No deviceSCSI ID#1: No deviceSCSI ID#2: No deviceSCSI ID#3: No deviceSCSI ID

Page 119

A-10MS-9246 1U Rackmount ServerSelect the SCSI device which you want to manage by highlighting the item and press<Enter>. The following dialog b

Page 120

B-1Adaptec SATA RAID Utility for Intel ICH5RThe southbridge ICH5R provides a hybrid solution that combines two indepen-dent SATA ports for support of

Page 121

B-2MS-9246 1U Rackmount ServerIntroduction1. OverviewAdaptec Embedded Serial ATA RAID with HostRAIDTM adds RAID functionality tothe Serial ATA I/O con

Page 122

B-3Adaptec SATA RAID Utility for Intel ICH5R Adaptec RAID Configuration (ARC) Utility—Part of the controller’s built-inBIOS code. You start ARC by pr

Page 123

B-4MS-9246 1U Rackmount ServerInstalling the DriverThis section describes installing the driver and setting up the new array for the drivesattached to

Comments to this Manuals

No comments