MSI MS-7021 Operations Instructions Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 14
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
Technical data MSI-SR4
Leuze electronic MSI-SR4 12
5 Technical data MSI-SR4
Category acc. to EN ISO 13849-1: 2009 4
Performance Level (PL) in accordance with
EN ISO 13849-1
PL e
Average probability of a failure to danger per
hour (PFH
d
)
2.0 x 10
-8
B10
d
DC 13: 10.0 million switching cycles
AC 15: 1.4 million switching cycles
Mean time to dangerous failure (MTTF
d
)73 years
Service life (T
M
)20 years
Stop category Stop 0 acc. to IEC 60204-1
Operating voltage U
B
24 V AC/DC, ±20%
Power consumption 3 W
External safeguarding for supply circuit 200 mA delay-action
Output contacts 3 normally open contacts, 1 normally closed contact (Ag
alloy)
Switching capacity of the contacts acc. to
EN 60947-5-1
AC-15: 230V / 5A 1.6 x 10
5
switching cycles
DC-13: 24V / 3A 1.3 x 10
5
switching cycles
Max. continuous current per current path 3 A
Ext. contact fuse protection per current path 5 A quick-action or 3.15 A delay-action
Max. switching frequency 3600 switching cycles/h
Mechanical life time 10 million switching cycles
Pickup delay – manual start 30 ms
Pickup delay (autom. start) 300 ms
Regression delay, response time 10 ms
Max. test pulse acceptance 1 ms
Time window for signal sequence monitoring 20 ms
Control voltage/current on S12, S22, S31 24V DC / 40 mA
Max. input current 100 mA
Admissible input line resistance < 30 W
Operating temperature 0° to +55° C
Storage temperature - 25° to +70° C
Overvoltage category
Dirt level
III for rated operating voltage 300 V AC
in accordance with VDE 0110 part 1
2
Interference emission EN 55011, DIN EN 61000-6-3
Interference rejection EN 61496-1: 2005 type 4
Protection rating Housing IP 40, terminals IP 20
Page view 11
1 2 ... 7 8 9 10 11 12 13 14

Comments to this Manuals