Safety
Leuze electronic MSI-SR4 5
2 Safety
Before using the E-STOP relay, a risk evaluation must be performed according to valid standards and
regulations.
For mounting, operating and testing, this document as well as all applicable national and international stan-
dards and regulations must be observed, printed out and handed to the affected personnel.
ª Before working with the E-STOP relay, completely read and understand the documents applicable to
your task.
In particular, the following national and international legal regulations apply for the start-up, technical
inspections and work with E-STOP relays:
Machinery directive 2006/42/EC
Use of Work Equipment Directive 89/655/EEC supplemented by Directive 95/63 EC
Accident-prevention regulations and safety rules
Other relevant standards
Standards
2.1 Symbols
2.2 Proper use
The E-STOP relay must only be used after it has been selected in accordance with the respectively appli-
cable instructions and relevant standards, rules and regulations regarding labor protection and occupa-
tional safety, and after it has been installed on the machine, connected, commissioned, and checked
by a competent person.
The safety interface device must be tested regularly by competent personnel.
Two switching contacts must always be looped into the switch-off circuit of the machine. To prevent
welding, relay switching contacts must be fused/protected externally according to the technical data.
The safety interface device must be exchanged after a maximum of 20 years. Repairs or the
exchange of parts subject to wear and tear do not extend the service life.
If an AOPD or other recommended safety component with lower safety category or Performance
Level is connected, the overall safety level for the corresponding path of the control cannot be higher
than that of the connected safety components.
The control of the machine or system that is to be safeguarded must be electrically influenceable. A
switch-off command initiated by an MSI must result in an immediate shutdown of the dangerous
movement.
The "Reset" acknowledgment button for unlocking the start/restart interlock must be mounted in such
a way that the entire danger zone can be seen from its mounting location.
Message outputs (state outputs) must not be used for switching safety-relevant signals.
In the event of changes to the MSI-SR4, all warranty claims against the manufacturer of the safety
interface device are rendered void.
Depending on external wiring, dangerous voltages may be present at the switching outputs. In addi-
tion to the power supply, these must be switched off and safeguarded against being switched back on
prior to all work on the MSI.
For contact multiplication of the release circuit, switching elements with positive-guided contacts
must be used.
Warning sign – This symbol indicates possible dangers. Please pay especially close
attention to these instructions!
WARNING
Improper or inappropriate use can result in danger to the life and limbs of the machine operator
or in damage to property.