MSI MS-9252 User Manual

Browse online or download User Manual for Motherboards MSI MS-9252. MSI MS-9252 User`s manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - User’s Manual for VariSpec

VariSpec™LIQUID CRYSTAL TUNABLE FILTERSUser’s Manual for VariSpecSeeing life in a new light

Page 2

6 — Introduction to VariSpec Liquid Crystal Tunable FiltersVariSpec Hardware ComponentsVariSpec filters consist of either a single module containing b

Page 3 - Contents

Introduction to VariSpec Liquid Crystal Tunable Filters — 7Figure 3. LNIR-06-20, Dual VariSpec with 20 mm OpticsVariSpec Filter Module• The entrance

Page 4

8 — Introduction to VariSpec Liquid Crystal Tunable Filters• Init LED flashes during data communication between the electronics controller module and

Page 5 - Chapter 1

Introduction to VariSpec Liquid Crystal Tunable Filters — 9Figure 5. Mounting Block and Adapters for 20 mm FilterFigure 6. Mounting Block and Adapter

Page 6 - Applications

10 — Introduction to VariSpec Liquid Crystal Tunable Filters

Page 7

Setting Up a VariSpec Filter — 11Chapter 2Setting Up a VariSpec FilterTopics in this chapter: Page• Unpacking the VariSpec Filter and Accessories...

Page 8 - About This Manual

12 — Setting Up a VariSpec FilterInstalling the VariSpec SoftwareCRi supplies a Windows-compatible SDK installation CD-ROM with each VariSpec filter.

Page 9 - CE Testing and Certification

Setting Up a VariSpec Filter — 132. The blinking LED indicates that the filter is initializing and exercising the liquid crystal (LC) elements in the

Page 10 - VariSpec Hardware Components

14 — Setting Up a VariSpec FilterFigure 8. 26-pin HD D-Sub cables connect to the VariSpec optics modules and electronics controller modules; USB cable

Page 11 - VariSpec Filter Module

Setting Up a VariSpec Filter — 15VsGui Program for Windows XP and Windows 7The VsGui demonstration program on the host can be used to verify correct

Page 12 - Mounting Block

CRi, 35-B Cabot Road, Woburn, MA, 01801, USA :: (Toll-Free US) 1-800-383-7924, (P) +1-781-935-9099, (F) +1-781-935-3388 :: [email protected] :: www.cr

Page 13

16 — Setting Up a VariSpec FilterFigure 11. VariSpec Sweep PanelThe VsGui program does not interface with commercial image-capture hardware, but the u

Page 14

Controlling VariSpec Filters — 17Chapter 3Controlling VariSpec FiltersTopics in this chapter: Page• Components of the VariSpec SDK ...

Page 15 - Chapter 2

18 — Controlling VariSpec FiltersNational Instruments® LabVIEW™ Sub-VIsCRi provides five sub-VI (virtual instrument) files for basic control of VariSp

Page 16

Controlling VariSpec Filters — 19Palette CommandsAfter the VariSpec filter has been initialized, there are two ways to select the passband wavelength

Page 17

20 — Controlling VariSpec FiltersTABLE 1. Control ModesLED BehaviorIf the VariSpec filter receives an incorrect communication, the Status LED turns Re

Page 18 - Device Manager

Controlling VariSpec Filters — 21The Status-Check character “@” provides various information on filter status. The VariSpec filter responds with a si

Page 19

22 — Controlling VariSpec FiltersAuto-Confirm format is selected using the “B” command, described later in this section. Upon power-up the VariSpec fi

Page 20

Controlling VariSpec Filters — 23BriefB <arg> <term>Command: If <arg> is 0, it selects the VariSpec filter’s normal format for repl

Page 21 - Chapter 3

24 — Controlling VariSpec FiltersIn brief format, the response would be:3<term>450<term>550<term>650<term>ExerciseE <arg>

Page 22 - Commands

Controlling VariSpec Filters — 25amount from its present wavelength, upon receipt of an eXecute command or an external hardware trigger pulse in mode

Page 23 - Palette Commands

Contents — iContentsChapter 1, Introduction to VariSpec Liquid Crystal Tunable Filters 1Introduction...

Page 24 - LED Behavior

26 — Controlling VariSpec FiltersNote: it is bad practice to query the awake/sleep status, as a sleeping filter will not reply.VersionV <arg> &l

Page 25 - Command Nomenclature

Controlling VariSpec Filters — 27Query reply: temperature of LC elements inoptics module in centigradeEscape<esc> (ASCII character code 27)This

Page 26 - Table of Commands

28 — Controlling VariSpec FiltersTABLE 5. Error CodesProgramming ExamplesHere are several examples of how the VariSpec filter may be programmed, using

Page 27

Controlling VariSpec Filters — 29W 500 <c/r> {tune filter to 500 nm}W 600 <c/r> {tune filter to 600 nm}W 488 <c/r> {tune filter

Page 28

30 — Controlling VariSpec FiltersExample 3. Cycling through various wavelengths using the TTL Sync port on the XNIR-09-20Here we define a palette and

Page 29

Frequently Asked Questions & Troubleshooting — 31Chapter 4Frequently Asked Questions &TroubleshootingFAQsI want to clean the glass surface of

Page 30

32 — Frequently Asked Questions & Troubleshootingmodels. The actual width of the passband is constant in terms of center wavenumber, but varies in

Page 31 - Error Codes

Frequently Asked Questions & Troubleshooting — 33Tests (such as CE testing) have shown the enclosure to be resistant to EMI. Nevertheless, exposi

Page 32 - Programming Examples

34 — Frequently Asked Questions & TroubleshootingWhen I connect the USB cable from the VariSpec filter’s Electronics Controller module to my compu

Page 33

Frequently Asked Questions & Troubleshooting — 35approach to harness reliable data from slides, compared to approaches that use color images acqu

Page 34

ii — ContentsProgramming Examples...

Page 35 - Chapter 4

36 — Frequently Asked Questions & Troubleshooting

Page 36

System Specifications & Dimensions — 37Appendix A. System Specifications & DimensionsOperating SpecificationsNote that these specifications r

Page 37

38 — System Specifications & DimensionsMechanical Dimensions (Optics Module)VariSpec 22 mm Aperture Standard EnclosureFigure 12. Exterior of a 22

Page 38

System Specifications & Dimensions — 39VariSpec 22 mm Aperture Enclosure for the XNIR-09-20 ModelFigure 14. Exterior of the Unique XNIR-09-20 Du

Page 39

40 — System Specifications & DimensionsVariSpec Mounting Adapters for 22 mm Aperture ModelsFigure 15. Stainless Steel Insert — Default, BlankFigur

Page 40

System Specifications & Dimensions — 41Figure 17. Stainless Steel Insert — Male C-mountFigure 18. Stainless Steel Insert — Male T-mountDWG# MM702

Page 41 - Dimensions

42 — System Specifications & DimensionsFigure 19. 52 mm Camera Lens Thread AdapterStandard 22 mm Aperture Filter Mounting BlockFigure 20. VariSpec

Page 42 - DWG# MD15285

System Specifications & Dimensions — 43VariSpec 22 mm Aperture Enclosure for the LNIR-20-20 ModelFigure 21. Exterior of the Unique LNIR-20-20 Enc

Page 43

44 — System Specifications & DimensionsDovetail SpacerFigure 23. Dovetail Spacer, Large ApertureDovetail C-MountsFigure 24. Dovetail, Female C-Mou

Page 44 - DWG# MM70228

System Specifications & Dimensions — 45Figure 25. Dovetail, Male C-Mount, Large ApertureFigure 26. Dovetail, T-mountDWG# MM70227-LADWG# MI10846

Page 45

Introduction to VariSpec Liquid Crystal Tunable Filters — 1Chapter 1Introduction to VariSpec LiquidCrystal Tunable FiltersThis chapter provides inform

Page 46 - DWG# MM70225

46 — System Specifications & DimensionsElectronics Controller ModuleFigure 27. Electronics Controller Module (for the XNIR-09-20 model only)Optics

Page 47

Operating Considerations — 47Appendix B. Operating ConsiderationsThis section supplies operating considerations with which you should be familiar to

Page 48 - Dovetail C-Mounts

48 — Operating ConsiderationsResponse Time versus TemperatureThe liquid crystal variable retarders set the response time of the filter, and their visc

Page 49 - Figure 26. Dovetail, T-mount

Operating Considerations — 49Given sufficient heat, delamination may occur. To cause delamination, two factors must be present: heat and stress. Mech

Page 50 - Electronics Controller Module

50 — Operating Considerations5. In the COMx Properties window (Figure 31), select the following settings: Bits per second: 115,200 (9600 for the XNIR-

Page 51 - Operating Considerations

Legacy Hardware and Software Considerations — 51Appendix C. Legacy Hardware and Software ConsiderationsOptics and Electronics Controller ModulesPrevi

Page 52 - Near-Infrared Warning

52 — Legacy Hardware and Software Considerations• VSGui Software Developer’s Kit and demonstration executable (revisions prior to 1.2): an obsolete st

Page 53 - Figure 30. Connect To

CRi Software End-User License Agreement — 53Appendix D. CRi Software End-User License AgreementThe following is an agreement (the “Agreement”) betwee

Page 54 - Figure 32. ASCII Setup

54 — CRi Software End-User License Agreementninety (90) days from the date of delivery. Your exclusive remedy under this Section 6 shall be, at CRi’s

Page 55 - Software Considerations

CRi Software End-User License Agreement — 55only in the state or federal courts in New York County, New York State, and you hereby consent to the exc

Page 56

2 — Introduction to VariSpec Liquid Crystal Tunable Filtersrandomly-polarized beam. VIS models contain an integral, non-removable hot mirror for block

Page 57 - License Agreement

56 — CRi Software End-User License Agreement

Page 58

VariSpec™ Quick Start Guide for a Windows®-based Host ComputerMD15473 Rev. B, August 2010CRi, 35-B Cabot Road, Woburn, MA, 01801, USA :: (Toll-Free US

Page 59

VariSpec™ Quick Start Guide for a Windows®-based Host ComputerMD15473 Rev. B, August 2010CRi, 35-B Cabot Road, Woburn, MA, 01801, USA :: (Toll-Free US

Page 60

Index — 59IndexAaluminum inserts, dimensions44angle-of-acceptance, specification 37aperture dual-housing enclosure, 22 mm 38aperture enclosure, 20 mm

Page 61 - -based Host Computer

60 — Indexmounting inserts 8Nnear-infrared warning48NIRR 2Ooff-axis performance3operating considerations 47operating temperature, specification 37Opti

Page 62

CRi, 35-B Cabot Road, Woburn, MA, 01801, USA :: (Toll-Free US) 1-800-383-7924, (P) +1-781-935-9099, (F) +1-781-935-3388 :: [email protected] :: www.cr

Page 63 - Index — 59

CRi, 35-B Cabot Road, Woburn, MA, 01801, USA :: (Toll-Free US) 1-800-383-7924, (P) +1-781-935-9099, (F) +1-781-935-3388 :: [email protected] :: www.cr

Page 64 - 60 — Index

Introduction to VariSpec Liquid Crystal Tunable Filters — 3Glossary of VariSpec LCTF TerminologyBandwidthThe Full-Width at Half-Maximum (FWHM), measu

Page 65 - Warranty

4 — Introduction to VariSpec Liquid Crystal Tunable FiltersOperator and Equipment SafetyIt is the responsibility of the purchaser to ensure that all p

Page 66

Introduction to VariSpec Liquid Crystal Tunable Filters — 5Your particular VariSpec LCTF may include additional support documentation from third-part

Comments to this Manuals

No comments