Report No 085006R-ITCEP07V04
Page: 100 of 162
c) 7 for equipment which is:
attended whilst in use (for example: hair dryers, vacuum cleaners, kitchen equipment
such as mixers, garden equipment such as lawn mowers, portable tools such as
electric drills), or
switched on automatically, or is intended to be switched on manually, no more than
twice per day, and also has either a delayed restart (the delay being not less than a
few tens of seconds) or manual restart, after a power supply interruption.
P
st
and P
1t
requirements shall not be applied to voltage changes caused by manual switching.
7.4. Test Procedure
The EUT is supplied in series with power analyzer from a power source having the same
normal voltage and frequency as the rated supply voltage and the equipment under test.
And the rated voltage at the supply voltage of EUT of 0.94 times and 1.06 times shall be
performed.
7.5. Deviation from Test Standard
No deviation.