Report No 085006R-ITCEP07V04
Page: 82 of 162
Site : SITE-1 Time : 2008/04/29 - 04:56
Limit : CISPR_B_10M_QP Margin : 6
EUT : Personal Computer Probe : 2007_Site1(2921)_10M - VERTICAL
Power : AC 230V/50Hz Note : MODE 2
Frequency
(MHz)
Correct Factor
(dB)
Reading Level
(dBuV)
Measure Level
(dBuV/m)
Margin
(dB)
Limit
(dBuV/m)
Detector Type
1 47.340 10.298 10.200 20.498 -9.502 30.000 QUASIPEAK
2 138.000 13.526 12.300 25.826 -4.174 30.000 QUASIPEAK
3 162.880 12.165 11.500 23.665 -6.335 30.000 QUASIPEAK
4 177.800 11.266 12.400 23.666 -6.334 30.000 QUASIPEAK
5 201.750 11.625 7.500 19.124 -10.876 30.000 QUASIPEAK
6 356.100 18.779 11.600 30.379 -6.621 37.000 QUASIPEAK
7 * 500.000 22.412 11.020 33.432 -3.568 37.000 QUASIPEAK
Note:
1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or
average measurements as necessary.
2. " * ", means this data is the worst emission level.
3. Measurement Level = Reading Level + Correct Factor