Report No 085006R-ITCEP07V04
Page: 84 of 162
Site : SITE-1 Time : 2008/04/25 - 14:59
Limit : CISPR_B_10M_QP Margin : 6
EUT : Personal Computer Probe : 2007_Site1(2921)_10M - VERTICAL
Power : AC 230V/50Hz Note : MODE 3
Frequency
(MHz)
Correct Factor
(dB)
Reading Level
(dBuV)
Measure Level
(dBuV/m)
Margin
(dB)
Limit
(dBuV/m)
Detector Type
1 118.000 13.278 9.600 22.878 -7.122 30.000 QUASIPEAK
2 183.870 10.560 10.100 20.660 -9.340 30.000 QUASIPEAK
3 216.000 10.560 10.700 21.260 -8.740 30.000 QUASIPEAK
4 * 240.000 13.304 17.900 31.204 -5.796 37.000 QUASIPEAK
5 307.190 15.986 7.900 23.886 -13.114 37.000 QUASIPEAK
6 500.000 20.812 6.200 27.012 -9.988 37.000 QUASIPEAK
7 633.940 23.011 4.800 27.811 -9.189 37.000 QUASIPEAK
Note:
1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or
average measurements as necessary.
2. " * ", means this data is the worst emission level.
3. Measurement Level = Reading Level + Correct Factor