Report No 085006R-ITCEP07V04
Page: 83 of 162
Site : SITE-1 Time : 2008/04/25 - 15:17
Limit : CISPR_B_10M_QP Margin : 6
EUT : Personal Computer Probe : 2007_Site1(2921)_10M - HORIZONTAL
Power : AC 230V/50Hz Note : MODE 3
Frequency
(MHz)
Correct Factor
(dB)
Reading Level
(dBuV)
Measure Level
(dBuV/m)
Margin
(dB)
Limit
(dBuV/m)
Detector Type
1 120.700 13.423 8.400 21.823 -8.177 30.000 QUASIPEAK
2 186.470 10.569 12.100 22.669 -7.331 30.000 QUASIPEAK
3 * 240.000 13.304 21.500 34.804 -2.196 37.000 QUASIPEAK
4 310.600 16.116 7.800 23.916 -13.084 37.000 QUASIPEAK
5 500.000 20.812 5.500 26.312 -10.688 37.000 QUASIPEAK
6 623.970 22.780 5.800 28.580 -8.420 37.000 QUASIPEAK
7 719.970 24.100 8.000 32.100 -4.900 37.000 QUASIPEAK
8 815.960 24.998 2.300 27.298 -9.702 37.000 QUASIPEAK
Note:
1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or
average measurements as necessary.
2. " * ", means this data is the worst emission level.