Page view 34
Report No 085006R-ITCEP07V04
Page: 32 of 162
Site : SR-1 Time : 2008/04/29 - 01:12
Limit : CISPR_B_00M_AV Margin : 0
EUT : Personal Computer Probe : LISN-N(023) - Line2
Power : AC 230V/50Hz Note : MODE 2
Frequency
(MHz)
Correct Factor
(dB)
Reading Level
(dBuV)
Measure Level
(dBuV)
Margin
(dB)
Limit
(dBuV)
Detector Type
1 * 0.197 0.300 42.920 43.220 -11.437 54.657 AVERAGE
2 0.404 0.310 33.010 33.320 -15.423 48.743 AVERAGE
3 0.748 0.320 30.590 30.910 -15.090 46.000 AVERAGE
4 1.326 0.330 27.430 27.760 -18.240 46.000 AVERAGE
5 1.693 0.340 30.900 31.240 -14.760 46.000 AVERAGE
6 15.552 0.900 28.900 29.800 -20.200 50.000 AVERAGE
Note:
1. All Reading Levels are Quasi-Peak and average value.
2. " * ", means this data is the worst emission level.
3. Measurement Level = Reading Level + Correct Factor