Report No 085006R-ITCEP07V04
Page: 35 of 162
Site : SR-1 Time : 2008/05/19 - 14:07
Limit : CISPR_B_00M_AV Margin : 0
EUT : Personal Computer Probe : LISN-L(023) - Line1
Power : AC 230V/50Hz Note : MODE 3
Frequency
(MHz)
Correct Factor
(dB)
Reading Level
(dBuV)
Measure Level
(dBuV)
Margin
(dB)
Limit
(dBuV)
Detector Type
1 * 0.205 0.615 45.210 45.825 -8.604 54.429 AVERAGE
2 0.265 0.311 41.520 41.831 -10.883 52.714 AVERAGE
3 0.556 0.300 36.040 36.340 -9.660 46.000 AVERAGE
4 0.986 0.310 32.110 32.420 -13.580 46.000 AVERAGE
5 1.970 0.340 32.540 32.880 -13.120 46.000 AVERAGE
6 4.107 0.400 31.430 31.830 -14.170 46.000 AVERAGE
Note:
1. All Reading Levels are Quasi-Peak and average value.
2. " * ", means this data is the worst emission level.
3. Measurement Level = Reading Level + Correct Factor