Report No 085006R-ITCEP07V04
Page: 17 of 162
Conducted susceptibility
As what is concluded in the document from Note2 of clause 5.4.6.2 of ISO/IEC 17025:
1999[2], the requirements for measurement uncertainty in CS testing are deemed to have
been satisfied, and the testing is reported in accordance with the relevant CS standards.
The immunity test signal from the CS system meet the required specifications in IEC
61000-4-6 through the calibration for unmodulated signal and monitoring for the test level
with the uncertainty evaluation report for the injected modulated signal level through CDN
and EM Clamp/Direct Injection as being 3.72 dB and 2.78 dB.
Power frequency magnetic field
As what is concluded in the document from Note2 of clause 5.4.6.2 of ISO/IEC 17025:
1999[2], the requirements for measurement uncertainty in PFM testing are deemed to have
been satisfied, and the testing is reported in accordance with the relevant PFM standards.
The immunity test signal from the PFM system meet the required specifications in IEC
61000-4-8 through the calibration report with the calibrated uncertainty for the Gauss Meter
to verify the output level of magnetic field strength as being 2 %.
Voltage dips and interruption
As what is concluded in the document from Note2 of clause 5.4.6.2 of ISO/IEC 17025:
1999[2], the requirements for measurement uncertainty in DIP testing are deemed to have
been satisfied, and the testing is reported in accordance with the relevant DIP standards.
The immunity test signal from the DIP system meet the required specifications in IEC
61000-4-11 through the calibration report with the calibrated uncertainty for the waveform of
voltage and timing as being 1.63 % and 2.76%.