Report No 085006R-ITCEP07V04
Page: 28 of 162
Site : SR-1 Time : 2008/04/29 - 01:11
Limit : CISPR_B_00M_QP Margin : 0
EUT : Personal Computer Probe : LISN-L(023) - Line1
Power : AC 230V/50Hz Note : MODE 2
Frequency
(MHz)
Correct Factor
(dB)
Reading Level
(dBuV)
Measure Level
(dBuV)
Margin
(dB)
Limit
(dBuV)
Detector Type
1 * 0.187 0.739 52.870 53.609 -11.334 64.943 QUASIPEAK
2 0.474 0.300 43.730 44.030 -12.713 56.743 QUASIPEAK
3 0.720 0.310 41.440 41.750 -14.250 56.000 QUASIPEAK
4 1.072 0.320 43.250 43.570 -12.430 56.000 QUASIPEAK
5 1.619 0.330 41.190 41.520 -14.480 56.000 QUASIPEAK
6 15.744 1.010 28.550 29.560 -30.440 60.000 QUASIPEAK
Note:
1. All Reading Levels are Quasi-Peak and average value.
2. " * ", means this data is the worst emission level.
3. Measurement Level = Reading Level + Correct Factor