Report No: 085006R-ITCEP07V04
Page: 43 of 162
4.4. Test Procedure
Telecommunication Port:
The mains voltage shall be supplied to the EUT via the LISN when the measurement of
telecommunication port is performed. The common mode disturbances at the
telecommunication port shall be connected to the ISN, which is 150 ohm impedance.
Both alternative cables are tested related to the LCL requested. The measurement range is
from 150kHz to 30MHz. The bandwidth of measurement is set to 9kHz.
The 75dB LCL ISN is used for cat. 6 cable, the 65dB LCL ISN is used for cat. 5 cable, 55dB
LCL ISN is used for cat. 3.
4.5. Deviation from Test Standard
No deviation.