MSI MS-6496 User Manual Page 84

  • Download
  • Add to my manuals
  • Print
  • Page
    / 165
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 83
Report No 085006R-ITCEP07V04
Page: 81 of 162
Site : SITE-1 Time : 2008/04/29 - 05:26
Limit : CISPR_B_10M_QP Margin : 6
EUT : Personal Computer Probe : 2007_Site1(2921)_10M - HORIZONTAL
Power : AC 230V/50Hz Note : MODE 2
Frequency
(MHz)
Correct Factor
(dB)
Reading Level
(dBuV)
Measure Level
(dBuV/m)
Margin
(dB)
Limit
(dBuV/m)
Detector Type
1 133.000 13.822 12.000 25.822 -4.178 30.000 QUASIPEAK
2 * 181.800 11.094 15.200 26.294 -3.706 30.000 QUASIPEAK
3 210.000 11.567 7.000 18.567 -11.433 30.000 QUASIPEAK
4 240.000 14.124 12.650 26.774 -10.226 37.000 QUASIPEAK
5 320.000 17.560 10.200 27.760 -9.240 37.000 QUASIPEAK
6 500.000 22.412 10.250 32.662 -4.338 37.000 QUASIPEAK
7 625.400 24.708 2.300 27.008 -9.992 37.000 QUASIPEAK
Note:
1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or
average measurements as necessary.
2. " * ", means this data is the worst emission level.
3. Measurement Level = Reading Level + Correct Factor
Page view 83
1 2 ... 79 80 81 82 83 84 85 86 87 88 89 ... 164 165

Comments to this Manuals